Aim the shunt tube where the fluid is

A digital twin built from a patient’s CT picks a better entry point and depth than the usual fixed Keen’s-point mark — so more of the tube floats freely in cerebrospinal fluid instead of getting buried in tissue.

Why it matters

When a brain shunt tube clogs, patients often need another operation; freehand aiming from a fixed scalp mark leaves the tip floating freely in fluid in only about one case in ten. This study shows that choosing entry and depth from each person’s own CT — still executed freehand with a ruler — put the tip free in fluid in 10 of 11 adults, versus 22 of 213 in older records.

The paper

Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning

Kritsanavis Chongsrid, Vich Yindeedej, Supaporn Konmun, Xulei Yang & Si Yong Yeo. arXiv:2610.20074 [cs.CV], submitted 14 Oct 2026. Read on arXiv · PDF

In plain language: catheter obstruction is the commonest cause of shunt failure. The team rebuilt skull, scalp, ear and ventricles from preoperative CT with deterministic geometry, searched every entry around Keen’s point for the perpendicular path with the longest stretch inside the ventricle under safety limits, and handed the surgeon two ruler measurements from the ear plus two depths. In an IDEAL Stage 2a series of 11 consecutive adults, freehand execution scored Hayhurst Grade 1 in 10 of 11 versus 22 of 213 historically (p = 9×10⁻⁹), with median entry deviation 2.5 mm, angular deviation 5.9°, 1.4 cm more intraventricular catheter than Keen’s point, and no intraoperative complication. The technique itself was unchanged; the gain came from choosing entry and depth per patient. Whether that lowers revisions is the next-stage hypothesis.

Try it

Illustrative side-view toy: fixed Keen’s-point aiming versus a patient-specific entry and depth. Numbers lean on the paper’s Grade-1 rates (22/213 vs 10/11) and +1.4 cm intraventricular length. Not surgical guidance and not the authors’ software.

Keen’s IV length (toy)
Optimized IV length (toy)
Your tip grade (toy)
Study vs history Grade 1

Side schematic: skull, ventricle, trajectories
Keen’s fixedDigital-twin planVentricle (CSF)Scalp / skull
Grade-1 placement: history vs study
Historical ~10% (22/213)Study 10/11Your toy Grade 1?

The maths in this page

The digital twin searches candidate entries around Keen’s point and keeps the perpendicular trajectory that maximises intraventricular catheter length under safety constraints. This toy approximates that idea on a 2-D side view:

LIV = length of catheter segment that lies inside the ventricle ellipse

Hayhurst Grade 1 in the paper means the tip sits free in CSF. In the toy, Grade 1 is awarded when the tip lies inside the ventricle with a small clearance from the wall; otherwise the tip is treated as buried (not Grade 1).

This is an illustrative geometry toy grounded in published rates and the +1.4 cm IV-length gain — not the authors’ CT pipeline, not a planner, and not advice for surgery.

How to use it

Start with a mid-size ventricle and a few millimetres of Keen’s error: watch the orange fixed path skim or miss the fluid space while the green plan keeps a longer stretch inside. Shrink the ventricle to see how a fixed landmark fails more often, then nudge planned offset and depth to recover Grade 1 and the extra centimetre-plus of tube in fluid. Toggle the digital-twin path off to compare Keen’s alone. The takeaway from the paper: the freehand technique stayed the same; choosing entry and depth from each patient’s CT is what moved Grade 1 from roughly one in ten to ten of eleven — whether that cuts revisions is still an open next-stage question.