Cancer-scan copper from plain zinc
Copper-64 lights up tumours on PET scans and can also treat them, but today it is made from a rare, enriched nickel that costs about US$50,000 a gram. This team shone a laser-driven fusion neutron source on ordinary zinc for one hour. The only radioactive copper they could find in it afterwards was copper-64.
Why it matters
Copper-64 can both image and treat prostate, brain and skin cancers, but it is made today from enriched nickel-64 at about US$50,000 per gram, which keeps it out of most clinics. This experiment made it instead from natural zinc at about US$24 per gram, roughly 2,000 times cheaper, and found no other radioactive copper, giving a purity of at least 99.62% and 99.97% after the paper’s detection-limit correction, above the 99.95% ultra-high-purity bar.
The paper
Direct Production of Ultra-High Radioisotopic Pure 64Cu from Natural Zinc Metal via D-D Fusion Narrowband Fast Neutron Source Irradiation
Jeremy M. C. Brown, Mantas Grigalavicius, Tibor Gilinger, Adam Kovacs, Parvin Varmazyar, Hsin-Hui Huang, Saulius Juodkazis, Mikas Vengris, Darius Gailevicius & Karoly Osvay (Swinburne University of Technology, Vilnius University, University of Szeged, ELI-ALPS, ELI ERIC). arXiv:2610.31340 [physics.med-ph], submitted 22 Oct 2026. Read on arXiv · PDF
In plain language: when a fast neutron hits a zinc-64 nucleus, it can knock out a proton and turn the zinc into copper-64 (the 64Zn(n,p)64Cu reaction). Natural zinc also contains zinc-66, -67, -68 and -70, which can turn into unwanted copper-66, -67 and -68. Copper-67 is the real problem, because its 61.8-hour half-life is longer than copper-64’s 12.7 hours and it cannot be removed chemically. Reactor neutrons make too much of it.
The team used the LEIA beamline at the ELI-ALPS laser facility in Hungary. A 1 kHz laser fires deuterons from a sheet of heavy water into a second heavy-water layer, where deuterium–deuterium fusion releases neutrons with a narrow spread of energies around 3.1 ± 0.5 MeV, about 2 × 10⁷ per second. At that energy the reactions make copper-64 about 682 times faster than copper-67. A 5 mm zinc pellet was irradiated for one hour, then measured with a germanium gamma-ray detector for 6 hours in every 12 over the next 72 hours. Only copper-64’s gamma lines appeared, decaying with its 12.7-hour half-life. Copper-66 and -68 had died away during the 0.67 hours it took to move the sample, and copper-67 stayed below the detection limit.
Try it
This calculator solves the paper’s Bateman production and decay equations for the four radioactive coppers, using the relative production rates and half-lives in the paper’s Table II. The absolute copper-64 activity is calibrated to the six measured activities in Table I. Purity does not depend on the source strength or the zinc mass, only on the timing. The scale-up sliders assume activity grows in proportion to source strength × zinc mass with the same geometry, which is an optimistic simplification.
What the paper measured
| Result | Value |
|---|---|
| Neutron source: D-D fusion, mean energy / average output | 3.1 ± 0.5 MeV / 2 × 10⁷ n/s over 4π |
| Sample: compacted natural zinc powder, 99.995% pure, 5 mm × 5 mm cylinder | 1 h irradiation |
| Copper-64 activity at mid-measurement times 3.63, 15.63 … 63.63 h | 17.10, 8.96, 4.59, 2.36, 1.15, 0.60 Bq |
| Detection limits (MDA): ⁶⁴Cu / ⁶⁶Cu / ⁶⁷Cu / ⁶⁸Cu | 0.223 / 0.462 / 0.065 / 0.085 Bq |
| Copper radioisotopes detected | ⁶⁴Cu only |
| Copper-64 purity, worst case (⁶⁷Cu at its 0.065 Bq limit), 0.67 h after | 99.62 ± 1.53% |
| Copper-64 purity with expected ⁶⁷Cu of 0.005 Bq (from Table II) | 99.97 ± 1.54% |
| Production ratio ⁶⁴Cu : ⁶⁷Cu at these neutron energies | 682 : 1 |
| Raw material: enriched ⁶⁴Ni vs natural zinc | US$50,000/g vs US$24/g (~2,000×) |
Sources: Tables I–II and text of arXiv:2610.31340. The paper’s Fig. 4 reports the 99.95% bar being crossed about 0.8 h after a 1 h irradiation and held for about another 31 h. This demo’s constant-rate Bateman model using the Table II numbers crosses at about 0.3 h and holds for about 11 h. The paper does not give enough detail to reproduce Fig. 4 exactly, so treat the demo’s window as a recalculation, not the paper’s figure.
The maths
Each copper isotope i is made at a constant rate Ri = fi R while the neutrons are on, where fi is its fractional total cross-section (Table II), and decays with λi = ln 2 / T½,i. For an irradiation of length tirr, the activity A = λN is:
Copper-68 is fed through the 3.75-minute isomer ⁶⁸ᵐCu, so it uses the two-member Bateman solution for a parent P feeding a daughter D:
Radioisotopic purity is the copper-64 share of all copper activity. The free fit to the six measured points is a straight line through ln A versus time, and its slope gives T½ = −ln 2 / slope.
Half-lives used: ⁶⁴Cu 12.70 h, ⁶⁶Cu 0.08533 h, ⁶⁷Cu 61.83 h, ⁶⁸Cu 0.008583 h, ⁶⁸ᵐCu 0.0625 h. Simplifications: all mass-68 production is routed through ⁶⁸ᵐCu, which all becomes ⁶⁸Cu; the 21-second ⁶⁷Ni route to ⁶⁷Cu is treated as direct; there is no burn-up and no change in neutron output. The absolute scale R is fitted with T½ fixed at 12.7 h to Table I, giving about 21.4 Bq of copper-64 at the end of the 1 h run.
How to use it
- Irradiation time: longer runs make more copper-64, which saturates after a few half-lives. Copper-67 keeps building for longer because it lives longer, so the purity window shrinks. Try 1 h and then 12 h.
- Wait after irradiation: the first few minutes are dominated by short-lived copper-66. Once it has decayed, purity peaks. After that, the longer-lived copper-67 slowly gains on copper-64 until purity drops below 99.95%. The paper’s sample was first measured at 0.67 h.
- Source strength and zinc mass: these scale the amount of copper-64 but not its purity. The experiment made about 20 Bq. A single PET dose is millions of times more, which is why the authors see the next step as bright deuteron accelerators (an earlier paper from the same lab targets 10¹⁰ n/s), with clinical-scale production in about 5 years.
- Measured decay: the right-hand plot shows that the six real measurements fall on copper-64’s 12.7-hour decay, which is how the team knew the 0.511 MeV signal came only from copper-64.
Demo by Grok Bot for the Daily Research Explorer. Calculations run in your browser; measured values are quoted from arXiv:2610.31340. The 148 MBq dose is the labelled adult dose of the approved copper-64 dotatate PET agent, used here only as a size comparison.