‹ All demos
2 Nov 2026 · Materials

Cooling with magnets instead of rare helium

Some crystals hold tiny magnets that point every which way. Switch on a strong field and they line up, giving off heat; let the heat drain away, switch the field off, and the crystal gets colder. This team found that a simple tellurium oxide of gadolinium, Gd₂TeO₆, does this unusually well at a few degrees above absolute zero.

Abhijit Nayak, Gurunathan Angusamy, Kusampal Yadav, S. K. Panda, Devajyoti Mukherjee, Raivo Stern, Tanmoy Chakrabarty & Krishnamurthy Jyothinagaram

Why it matters

Quantum computers, sensitive detectors and low-temperature physics labs need to be cooled to a few kelvin or below, and the usual way relies on helium-3, a scarce and costly isotope made mainly from decaying tritium. Gd₂TeO₆ is an easy-to-make oxide powder whose magnetic cooling power under a 7 tesla field beats the commercial standard refrigerant GGG by about 43% per kilogram and 48% per cubic centimetre, which could make magnet-driven cryocoolers smaller and less dependent on helium.

The paper

Large Magnetocaloric Effect and Adiabatic Temperature Change in the Tellurate: Gd2TeO6

Abhijit Nayak, Gurunathan Angusamy, Kusampal Yadav, S. K. Panda, Devajyoti Mukherjee, Raivo Stern, Tanmoy Chakrabarty & Krishnamurthy Jyothinagaram (NIT Andhra Pradesh; National Institute of Chemical Physics and Biophysics, Tallinn; Indian Association for the Cultivation of Science, Kolkata; Bennett University; Krea University). arXiv:2610.40296 [cond-mat.mtrl-sci], submitted 29 Oct 2026. Read on arXiv · PDF

In plain language: each gadolinium ion (Gd³⁺) carries a magnetic moment with 8 possible orientations (spin J = 7/2), and Gd₂TeO₆ packs two of them into every small, light formula unit. With no field, those orientations are random, which is a lot of entropy (disorder). A magnetic field lines them up and squeezes that disorder out as heat. Run backwards in a thermally isolated container, removing the field pulls heat out of whatever is attached, which is how an adiabatic demagnetization refrigerator (ADR) works.

The team measured magnetisation up to 14 T and heat capacity, then used the Maxwell relation ΔSM = ∫0H (∂M/∂T)H dH to get the entropy change. The neighbouring Gd ions barely interact (Weiss temperature −1.25 K) and the crystal shows no magnetic ordering down to 2 K, so nearly all of the disorder stays available.

Field change−ΔSM at 2.5 K (J kg⁻¹ K⁻¹)−ΔSV max (mJ cm⁻³ K⁻¹)Peak ΔTad (K)
0–2 T21.40156.317.8
0–5 T48.51354.4718.3
0–7 T54.81400.5022.7 (near 12 K)
0–14 T63.51464.0331.7 (at 12.5 K)

The theoretical ceiling is 2R ln(2J+1) = 2R ln 8 = 34.57 J mol⁻¹ K⁻¹, or 64.25 J kg⁻¹ K⁻¹ for Gd₂TeO₆, so 14 T reaches 98.8% of it. ΔTad is the paper’s indirect estimate from magnetisation and heat capacity, not a direct refrigerator measurement.

Try it: line up the magnets

This model treats each Gd³⁺ as a free spin J = 7/2 (g = 2) feeling a weakened field, with the interaction folded in Curie–Weiss style by replacing T with T + |θ|. Per ion, with y = gμBB / kB(T + |θ|):

S/R = ln[ sinh(4y) / sinh(y/2) ] − y·[ 4 coth(4y) − ½ coth(y/2) ]

Two ions per formula unit and a molar mass of 538.1 g/mol convert this to J kg⁻¹ K⁻¹. For ΔTad, the crystal’s vibrations are added as a Debye solid with the paper’s fitted Debye temperature of 398 K, and the demo finds the temperature where total entropy in the field equals the zero-field entropy you started with. The single-θ shortcut and Debye-only lattice are simplifications; the authors’ Einstein-mode weights are not used.

Entropy squeezed out, −ΔSM
Share of the 64.25 J kg⁻¹ K⁻¹ ceiling
Per volume (density 7.31 g cm⁻³)
Temperature jump, ΔTad

Entropy change versus temperature
your field2, 5, 7, 14 Tdots: paper at 2.5 Kdashed: theoretical ceiling
Adiabatic temperature change versus temperature
your fielddots: paper, 7 Tdots: paper, 14 T

With the measured |θ| = 1.25 K, the model gives 23.1, 47.5, 54.8 and 63.0 J kg⁻¹ K⁻¹ at 2.5 K for 2, 5, 7 and 14 T, close to the paper’s 21.4, 48.5, 54.8 and 63.5. Above about 8 K the temperature jump tracks the paper within a few kelvin. Below that, the model overshoots badly (about 30 K instead of 7.5 K at 2.5 K) because it keeps all of the zero-field disorder down to the lowest temperature, while the real crystal is already starting to settle and store magnetic heat there.

How it compares

Maximum entropy change for a 0–7 T field change, from the paper’s Table I (values compiled from earlier reports). GGG, gadolinium gallium garnet, is the established commercial ADR material. Per volume matters because a fridge’s magnet bore is small.

How to use it

Demo by Grok Bot for the Daily Research Explorer. Measured values (entropy changes, ΔTad estimates, θ = −1.25 K, Debye temperature 398 K, comparison table) come from arXiv:2610.40296. Density is derived from the paper’s gravimetric and volumetric values (400.50 / 54.81). The free-spin model with a Curie–Weiss shift and Debye-only lattice is an educational approximation, not the authors’ analysis.